G3NA-290B-UTU DC5-24 solid state relay
G3NA-290B-UTU DC5-24 solid state relay
specification
Ratings | |
Product classification | Solid State Relay for heater control |
Operating Rated Voltage | 5 to 24 VDC |
Operating Voltage Range | 4 to 32 VDC |
Input Impedance | 15 mA Max.(at 25 CEL) |
Must Operate Voltage | 4 VDC Max. |
Must Release Voltage | 1 VDC Min. |
Isolation | Phototriac |
Output Form | SPST-NO |
Rated load voltage | 24 to 240 VAC (50/60Hz) |
Load Voltage Range | 19 to 264 VAC (50/60Hz) |
Load Current | AC: 1 A to 90 A (With heat sink (at 40 CEL))AC: 1 A to 7 A (Without a heat sink (at 40 CEL)) |
Inrush Current Resistivity | AC: 1000 A (60Hz 1 cycle) |
Output ON voltage drop | 1.6V(RMS) Max. |
Leakage current | 5mA Max. (at 100VAC)10mA Max. (at 200VAC) |
Ambient temperature | Operating: -30 CEL to 80 CELStorage: -30 CEL to 100 CEL(with no icing or condensation) |
Ambient humidity | Operating: 45% RH to 85% RH(with no icing or condensation) |
Characteristics | |
Operate time | 1/2 cycle of load power source + 1ms Max. |
Release time | 1/2 cycle of load power source + 1ms Max. |
Protection for output | Varisitor and Snubber |
Zero cross function | Provided |
Indicator | Equipped |
Insulation resistance | Between INPUT to LOAD: 100 M Ohm Min. (at 500 VDC)Between Heat Sink to INPUT/OUTPUT Terminals: 100 M Ohm Min. (at 500 VDC) |
Dielectric strength | Between INPUT to LOAD: 4000 VAC 50/60 Hz for 1 minBetween Heat Sink to INPUT/OUTPUT Terminals: 4000 VAC 50/60 Hz for 1 min |
Vibration resistance | 10 to 55 to 10Hz 0.75mm single amplitude(1.5mm double amplitude)XYZ directions for 2hrs each |
Shock resistance | 1000m/s2 each XYZX'Y'Z' directions for 3 times |
Applicable standard (UL) | Standard No.: UL508 , UL1950File number: NO.E64562 , NO.E64562 |
Applicable standard (CSA) | Standard No.: C22.2 NO.14 , C22.2 NO.950File number: No.LR35535 , No.LR35535 |
Applicable standard (TUV) | Standard No.: EN60947-4-3File number: NO.R 50042088 |
Terminal structure | screw |
Terminal strength (Clamp torque) | Input terminal: Recomendable fasten torque M4: 0.98 to 1.47N.mOutput terminal: Recomendable fasten torque M5: 1.57 to 2.45N.m |
Mounting | screw , panel , panel(DIN track) |
Weight | Approx. 120 g |